GET THE EMC D-PSC-MN-01 CERTIFICATION WITHIN THE TARGET PERIOD

Get the EMC D-PSC-MN-01 Certification within the Target Period

Get the EMC D-PSC-MN-01 Certification within the Target Period

Blog Article

Tags: D-PSC-MN-01 Test Dumps Free, D-PSC-MN-01 Pass Test, Valid D-PSC-MN-01 Test Duration, D-PSC-MN-01 Vce File, D-PSC-MN-01 Pdf Files

What's more, part of that 2Pass4sure D-PSC-MN-01 dumps now are free: https://drive.google.com/open?id=1Jsa0pgaP0pR-5e06qRA8LdOPl1AhM9f5

D-PSC-MN-01 practice materials stand the test of time and harsh market, convey their sense of proficiency with passing rate up to 98 to 100 percent. Easily being got across by exam whichever level you are, our D-PSC-MN-01 practice materials have won worldwide praise and acceptance as a result. They are 100 percent guaranteed D-PSC-MN-01 practice materials. The content of D-PSC-MN-01 practice materials are based on real exam by whittling down superfluous knowledge without delinquent mistakes rather than dropping out of reality. Being subjected to harsh tests of market, they are highly the manifestation of responsibility carrying out the tenets of customer oriented

EMC D-PSC-MN-01 Exam Syllabus Topics:

TopicDetails
Topic 1
  • PowerScale Implementation: Geared towards cluster administrators, this section covers the practical aspects of implementing PowerScale systems. It focuses on creating new clusters, integrating nodes into existing clusters, and applying alternative configurations or accessories to improve performance.
Topic 2
  • PowerScale Hardware Concepts: This part of the exam assesses the expertise of IT infrastructure architects, and emphasizes the ability to differentiate between the architectural elements of PowerScale platforms, understand their specific use cases, and compare design specifications across PowerScale hardware models.
Topic 3
  • PowerScale Hardware Maintenance: Targeted at system administrators, this section focuses on key tasks involved in maintaining PowerScale hardware. It examines candidates' proficiency in completing initial maintenance steps, preparing nodes for operation, and processing Field Replaceable Unit (FRU) and Customer Replaceable Unit (CRU) requests.
Topic 4
  • PowerScale Hardware Installation: This section evaluates the installation capabilities of hardware engineers to test candidates on their ability to plan and execute the installation of PowerScale hardware, prepare the maintenance site, and adhere to best practices when installing racks, nodes, and related components.

>> D-PSC-MN-01 Test Dumps Free <<

D-PSC-MN-01 Pass Test, Valid D-PSC-MN-01 Test Duration

For candidates who are going to choose the D-PSC-MN-01 practice materials, it’s maybe difficult for them to choose the exam dumps they need. If you choose us, D-PSC-MN-01 learning materials of us will help you a lot. With skilled experts to verify D-PSC-MN-01 questions and answers, the quality and accuracy can be ensured. In addition, we provide you with free demo to have a try before purchasing, so that we can have a try before purchasing. D-PSC-MN-01 Learning Materials also have high pass rate, and we can ensure you to pass the exam successfully.

EMC Dell PowerScale Maintenance Exam Sample Questions (Q105-Q110):

NEW QUESTION # 105
Which cable is required to connect to the A300 console?

  • A. VGA
  • B. RJ45
  • C. DB9-to-DB9
  • D. USB-to-USB

Answer: B

Explanation:
To connect to theA300console, a cable with anRJ45connector is required. The A300 node's console port uses an RJ45 interface for serial communication, allowing administrators to access the console for configuration and troubleshooting.
1. Understanding Console Connections on A300 Nodes:
* Console Port Type:
* The A300 node features an RJ45 serial console port.
* This port provides access to the node's console interface.
* Purpose of Console Access:
* Allows administrators to perform initial configurations.
* Useful for troubleshooting when network access is unavailable.
* Provides direct command-line access to the node.
2. Required Cable for Connection:
* RJ45 Serial Cable:
* A standard RJ45-to-DB9 serial console cable is typically used.
* One end has an RJ45 connector (plugs into the node).
* The other end may have a DB9 connector (plugs into a computer's serial port) or USB via a serial- to-USB adapter.
* Alternative Connection Methods:
* If the computer does not have a serial port, a USB-to-serial adapter can be used.
* Ensure the correct drivers are installed for the adapter.
3. Why Other Options Are Less Suitable:
* Option B: DB9-to-DB9
* The A300 uses an RJ45 port, not a DB9 port.
* A DB9-to-DB9 cable would not physically connect to the node.
* Option C: VGA
* VGA is used for video output, not serial console connections.
* The A300 does not use VGA for console access.
* Option D: USB-to-USB
* The A300 does not support console connections via USB-to-USB cables.
* USB ports on the node are typically for peripheral devices, not console access.
4. Steps to Connect to the A300 Console:
* Step 1:Obtain an RJ45-to-DB9 serial console cable.
* Step 2:Connect the RJ45 end to the console port on the A300 node.
* Step 3:Connect the DB9 end to the serial port on the computer (or use a USB-to-serial adapter if necessary).
* Step 4:Use a terminal emulator (e.g., PuTTY) configured with the appropriate serial settings (usually
115200 baud rate, 8 data bits, no parity, 1 stop bit).
5. Dell PowerScale References:
* Dell EMC PowerScale A300 Hardware Guide:
* Provides details on hardware components, including console port specifications.
* Dell EMC PowerScale A300 Hardware Guide
* Dell EMC PowerScale OneFS CLI Administration Guide:
* Discusses accessing the CLI via console connections.
* Dell EMC PowerScale OneFS CLI Guide
* Knowledge Base Articles:
* Article ID 000180127:"Connecting to the Console Port on PowerScale A-Series Nodes"
* Article ID 000180128:"Serial Console Connection Instructions for Dell PowerScale Nodes"


NEW QUESTION # 106
How can an administrator verify that a node is successfully shut down?

  • A. Execute the isi status -q command and see that the node is in a D--- status.
  • B. Try to access a share on the node and verify the share is inaccessible.
  • C. Execute the isi status -q command and see that the node is in an A-- status.
  • D. Verify the LEDs on the front panel are not lit.

Answer: A


NEW QUESTION # 107
An engineer replaced a failed node in a PowerScale H500 due to hardware issues. They must verity that the replacement node is functioning correctly.
What is a crucial step when replacing the failed node in the cluster?

  • A. Confirm that the replacement node inherits the old serial number from the cluster.
  • B. Verify the size of the storage capacity of the replacement node.
  • C. Power on the replacement node and ensure it connects to the network without any problems.
  • D. Run a diagnostic test on the replacement node.

Answer: D

Explanation:
After replacing a failed node in a PowerScale H500 cluster, it is crucial torun a diagnostic test on the replacement nodeto ensure it is functioning correctly and can integrate seamlessly into the cluster.
* Importance of Diagnostics:
* Verify Hardware Functionality:
* Ensures all components of the replacement node are working properly.
* Identify Potential Issues:
* Detects any hardware faults or configuration problems before the node joins the cluster.
* Diagnostic Procedures:
* Boot Diagnostics:
* During startup, the node performs POST (Power-On Self-Test).
* OneFS Healthcheck:
* Use the isi diagnostics commands to run health checks on the node.
* Cluster Integration Tests:
* Verify network connectivity, storage availability, and cluster communication.
* Steps to Run Diagnostics:
* Physical Inspection:
* Ensure all cables and components are properly connected.
* Power On the Node:
* Observe for any error lights or beep codes.
* Execute Diagnostic Commands:
* Run isi_hw_status to check hardware status.
* Use isi_diag tools for comprehensive testing.
* Review Logs:
* Check system logs for any error messages.
* Why Other Options Are Less Crucial:
* B. Confirm that the replacement node inherits the old serial number from the cluster:
* Serial numbers are hardware-specific and cannot be inherited.
* Nodes have unique serial numbers; cluster identity is managed logically.
* C. Verify the size of the storage capacity of the replacement node:
* While important, it's generally assumed that the replacement node matches the failed node's specifications.
* Not as crucial as ensuring the node functions correctly.
* D. Power on the replacement node and ensure it connects to the network without any problems:
* Necessary, but this is part of the diagnostic process.
* Running diagnostics encompasses powering on and verifying network connectivity.
Dell PowerScale References:
* Dell EMC PowerScale OneFS Administration Guide:
* Provides information on monitoring and diagnostics commands.
* Node Replacement Procedures in SolVe Online:
* Outline the steps for replacing nodes and the importance of running diagnostics.
* Best Practices for Cluster Maintenance:
* Emphasize verifying node health before adding it to the cluster.


NEW QUESTION # 108
Which cluster interface provides the most detailed network traffic statistics and enables file and directory operations on the cluster?

  • A. CLI
  • B. Serial console
  • C. Platform API
  • D. Web console

Answer: A

Explanation:
The Command Line Interface (CLI) provides the most comprehensive and detailed interaction with a Dell PowerScale cluster. Through the CLI, administrators have access to a wide range of commands that offer detailed network traffic statistics, system performance metrics, and the ability to perform granular file and directory operations.
While the Web console offers a user-friendly graphical interface for cluster management, it may not provide the same level of detail or the full set of functionalities available in the CLI. The Serial console is primarily used for initial setup or troubleshooting when network access is unavailable. The Platform API allows for programmatic access but requires additional development effort to utilize.
The CLI is accessible via SSH and provides tools like isi statistics for detailed performance metrics and isi commands for file system operations. This makes it the most powerful interface for administrators needing in- depth information and control over the cluster.
References:
* Dell PowerScale OneFS Command-Line Administration Guide
* Dell PowerScale OneFS CLI Reference Guide


NEW QUESTION # 109
What is the recommended way to install a Dell PowerScale Gen 6 compute module in a chassis?

  • A. Close the module lever and slide the module into the chassis until it clicks.
  • B. Loosen the thumbscrew on the release lever then slide the compute module into the chassis.
  • C. Slide the release lever to the right and guide the node into the chassis.
  • D. Support the node with both hands and slide it into the node bay.

Answer: D


NEW QUESTION # 110
......

They work together and strive hard to design and maintain the top standard of EMC D-PSC-MN-01 exam questions. So you rest assured that the D-PSC-MN-01 exam questions you will not only ace your Dell PowerScale Maintenance Exam certification exam preparation but also be ready to perform well in the final D-PSC-MN-01 Certification Exam. The D-PSC-MN-01 exam are the real D-PSC-MN-01 exam practice questions that will surely repeat in the upcoming Dell PowerScale Maintenance Exam (D-PSC-MN-01) exam and you can easily pass the exam.

D-PSC-MN-01 Pass Test: https://www.2pass4sure.com/Dell-Storage/D-PSC-MN-01-actual-exam-braindumps.html

BONUS!!! Download part of 2Pass4sure D-PSC-MN-01 dumps for free: https://drive.google.com/open?id=1Jsa0pgaP0pR-5e06qRA8LdOPl1AhM9f5

Report this page